.. Page 161 The indicator on the printer Faults manifest if the adapter turns orange, as well as printing printer adapter operates. Disconnect and hook up the fails. power adapter, ability about the printer adapter again, and verify if the printing is typical right after 1 minute. Web site 163: Electrical Safety Inspection
one.two.2 Warning Labels Warning Labels Indicating You should meticulously look at this guide right before use unit. The subsequent labels can be a. Never spot the device over a sloped surface area. If not the out there in the event the process system could slide, causing particular damage or maybe the machine works While using the mobile malfunction.
Evaluating people in currently’s demanding ecosystem requires innovative technologies that enables clinicians to create fast and confident diagnoses. The flexibility of the DP-50 expands your clinical utility when helping to improve individual care.
After you end the scanning and also the picture seize, you need to electricity from the technique and disconnect the system from your AC electricity provide, then pull out AC electric power cables. Web site 109: Battery Connecting Board
Learn greater diagnostic data as a result of prolonged see of the anatomical composition on all convex probes.
Return for the process preset interface. The option status adjustments into Uninstalled. The uninstalling functionality is exclusive to inner consumers.
Find better diagnostic info by means of extended look at with the anatomical framework on all linear probes
Mindray’s new era of black & white ultrasound technique, DP-50 Specialist, is supplied with Innovative imaging systems letting deeper penetration and quicker image acquisition with larger resolution.
Notice: In advance of uploading the log, make certain the ultrasound method continues to be connected to network, normally, the method could warn “couldn't connect with server” The server (smtp.
The chapter supplies the tactic to verify major functionality and general performance of products. That is only utilized for reference, not preventive execution. Function examining and testing of the element shall be carried out by Mindray services engineers and the person jointly. Page sixty six: Standard Exam
NOTE: Around the check, the brightness adjustment arrives in advance of distinction. Immediately after readjusting the observe’s distinction and brightness, regulate all preset and peripheral configurations.
Utmost 4 times tasking for one transmitted beam, leading to outstanding time resolution and better frame level.
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Not all services and products listed are offered outdoors the U.S. and some are subject matter to place distinct restrictions.
Click Agree and Carry on to accept cookies and go on to the website or click More Information to view in-depth descriptions of the types of cookies and opt for no matter whether to simply accept certain cookies whilst on the positioning.
five.two.three Geometric positioning precision Longitudinal geometric positioning accuracy Check Move: Do changes as the best way in tests the maximum depth. Record the distance by 20mm Just about every phase on the longitudinal targets line utilizing the measurement caliper; Find the worth with the best mistake (to 20mm), work out the precision utilizing the system down below The measurement caliper needs to be positioned with the upper edge of the target, NOTE:... Web page seventy nine Transverse geometric positioning precision Take a look at Action: Deal with the scan floor with the phantom with drinking water or couple gel, Carefully Make contact with the probe Along with the scan floor Modify the depth, creating the transverse targets to become exhibited from the picture. Modify the main target place for being posited beside the transverse targets (the Dp50rb login normal isn't clear) Change parameters like obtain, TGC, making Each individual transverse targets to get clearly shown. Web site 80 5.5.two.four Blackout Region Take a look at Stage: Address the scan surface with the phantom with water or couple gel, gently Call the probe Together with the scan area Adjust the depth in a reduce worth, and set the main focus at the nearest spot to the scan area. Lower the worth of parameters like AP, Obtain till the track record sound just is often viewed. Webpage eighty one: Application Improve And Servicing